[1]史雅绒,王培军,徐实谦,等.制作颊侧多曲簧的牙用不锈钢丝的性能分析[J].医学信息,2019,32(06):89-93.[doi:10.3969/j.issn.1006-1959.2019.06.028]
 SHI Ya-rong,WANG Pei-jun,XU Shi-qian,et al.Performance Analysis of Dental Stainless Steel Wire for Making Buccal Multi-curved Spring[J].Journal of Medical Information,2019,32(06):89-93.[doi:10.3969/j.issn.1006-1959.2019.06.028]
点击复制

制作颊侧多曲簧的牙用不锈钢丝的性能分析()
分享到:

医学信息[ISSN:1006-1959/CN:61-1278/R]

卷:
32卷
期数:
2019年06期
页码:
89-93
栏目:
论著
出版日期:
2019-03-15

文章信息/Info

Title:
Performance Analysis of Dental Stainless Steel Wire for Making Buccal Multi-curved Spring
文章编号:
1006-1959(2019)06-0089-05
作者:
史雅绒1王培军1徐实谦2石瑛琦1陈 萍1侯 录1
(1.哈尔滨医科大学附属第二医院口腔正畸科,黑龙江 哈尔滨 150081;2.哈尔滨工业大学材料科学与工程学院,黑龙江 哈尔滨 150001)
Author(s):
SHI Ya-rong1WANG Pei-jun1XU Shi-qian2SHI Ying-qi1CHEN Ping1HOU Lu1
(1.Department of Orthodontics,the Second Affiliated Hospital of Harbin Medical University,Harbin 150081,Heilongjiang,China;2.School of Materials Science and Engineering,Harbin Institute of Technology,Harbin 150001,Heilongjiang,China)
关键词:
φ0.8 mm牙用不锈钢丝颊侧多曲簧力学性能
Keywords:
Φ0.8 mm dental stainless steel wireBuccal multi-curved springMechanical properties
分类号:
R783
DOI:
10.3969/j.issn.1006-1959.2019.06.028
文献标志码:
A
摘要:
目的 通过测试并比较480℃加热退火处理的四种不同品牌,直径为φ0.8 mm牙用不锈钢丝的电镜断口形貌和拉伸断裂机制,为临床选用适宜的牙用不锈钢丝制备颊侧多曲簧提供一定的参考。方法 选用弯制颊侧多曲簧的直径为φ0.8 mm的上齿牌、上海康桥牌、锋棱牌、上海荣祥牌的牙用不锈钢丝,应用万能拉伸仪测量比较四种材料480℃加热退火后的拉伸试验、金相组织微观测试及EDX能谱分析。结果 四种不同品牌的牙用不锈钢丝在480℃加热退火处理下,直径为φ0.8 mm锋棱牌牙用不锈钢丝拉伸能力最好,电镜观察见韧窝大小不一,深浅有别,Ni含量最高,更适合临床弯制颊侧多曲簧。结论 直径为φ0.8 mm锋棱牌牙用不锈钢丝较其他品牌牙用不锈钢丝,更适合弯制颊侧多曲簧,可考虑临床应用。
Abstract:
Objective To test and compare the electron microscopic fracture morphology and tensile fracture mechanism of four different brands of dental stainless steel wire with diameter φ0.8 mm heated and annealed at 480℃, and prepare the buccal multi-curve for the clinical selection of dental stainless steel wire. The spring provides a certain reference. Methods The upper teeth of the curved cheek side multi-curved spring with diameter φ0.8 mm, Shanghai Kangqiao brand, Fengling brand, Shanghai Rongxiang brand dental stainless steel wire were selected, and the four materials 480℃ were measured by universal tensile tester. Tensile test after heating and annealing, metallographic microstructure microscopic test and EDX spectrum analysis. Results Four different brands of dental stainless steel wire were heated and annealed at 480℃. The diameter of φ0.8 mm was the best for the stainless steel wire. The electron microscopic observation showed that the dimples were different in size and different in depth. The highest Ni content is more suitable for clinically curved buccal multi-curved springs. Conclusion The φ0.8 mm diameter ribbed stainless steel wire is more suitable for bending the buccal multi-curved spring than other brands of dental stainless steel wire, which can be considered for clinical application.

参考文献/References:

[1]刘潇遥,王培军,徐实谦,等.正畸用颊侧多曲簧双侧矫治力的实验研究[J].医学信息,2018,31(14):85-87,91. [2]徐舰,王培军,徐实谦,等.颊侧多曲簧对牙列两侧产生矫治力的对比研究[J].医学信息,2018,31(13):156-159. [3]侯录,徐实谦.颊侧多曲黃矫治器及颊侧多曲簧胎具,ZL200620021913,2中华人民共和国国家知识产权局(证书):第965078号. [4]张婉楠,侯录,徐实谦.颊侧多曲簧活动矫治临床应用中的生物学效应[J].中国组织工程研究,2014,18(8):1277-1282. [5]段银钟.安氏Ⅲ类错牙合正畸诊断与治疗[M].北京:人民军医出版社,2014:2-6. [6]陈治清.口腔材料学[M].第3版.北京:人民卫生出版社,2003:15,22,151. [7]高晓哲.预拉伸奥氏体不锈钢(S30408)组合焊焊接接头低温力学性能研究[D].浙江大学,2017. [8]王韶华,沈翃,国栋,等.含Cr合金化钢组织及性能分析[J].河北工业科技,2018,35(6):421-425. [9]张云龙,王玉强,王爱玲.影响钢管3PE防腐层离线拉伸试验结果的因素分析[J].钢管,2018,47(3):61-65. [10]薛河,李凯,王帅,等.冷加工过程中316L奥氏体不锈钢硬度压痕尺寸效应分析[J].中国机械工程,2019(1):105-112.