[1]李 儒,胡知文.多排CT及后处理技术在节育器异位中的临床应用[J].医学信息,2019,32(19):165-167.[doi:10.3969/j.issn.1006-1959.2019.19.055]
 LI Ru,HU Zhi-wen.Clinical Application of Multi-row CT and Post-processing Techniques in Ectopic Device[J].Journal of Medical Information,2019,32(19):165-167.[doi:10.3969/j.issn.1006-1959.2019.19.055]
点击复制

多排CT及后处理技术在节育器异位中的临床应用()
分享到:

医学信息[ISSN:1006-1959/CN:61-1278/R]

卷:
32卷
期数:
2019年19期
页码:
165-167
栏目:
诊疗技术
出版日期:
2019-10-01

文章信息/Info

Title:
Clinical Application of Multi-row CT and Post-processing Techniques in Ectopic Device
文章编号:
1006-1959(2019)19-0165-03
作者:
李 儒 胡知文
(湖北省英山县人民医院CT室,湖北 英山 438700)
Author(s):
LI RuHU Zhi-wen
(CT Room,Yingshan County People's Hospital,Yingshan 438700,Hubei,China)
关键词:
官内节育器异位体层摄影术X线计算机后处理技术
Keywords:
Intrauterine deviceEctopicTomographyX-ray computerPost-processing technique
分类号:
R814.3;R169.41
DOI:
10.3969/j.issn.1006-1959.2019.19.055
文献标志码:
A
摘要:
目的 探讨多排CT及后处理技术(VR、MPR、CPR)在节育器异位诊断中的应用价值。方法 回顾性分析本院2013年6月~2018年7月经膀胱镜、宫腔镜、肠镜、腹腔镜或传统开腹手术确诊的节育器异位患者28例的临床资料,分析CT在节育器异位时观察节育器异位的位置及与周围组织的位置关系的准确程度。结果 28例中CT准确结果与手术结果分别为:异位于膀胱14、14例,直肠4、5例,回盲区1、1例,子宫直肠间隙5、5例,子宫膀胱间隙2、2例,子宫左侧旁1、1例。结论多排CT及后处理技术在节育环异位定位中的诊断准确率较高,有助于临床术前治疗方案的确定。
Abstract:
Objective To explore the application value of multi-row CT and post-processing techniques (VR, MPR, CRP) in the diagnosis of contraceptive ectopic.Methods A retrospective analysis of clinical data of 28 cases of ectopic patients diagnosed by cystoscopy, hysteroscopy, colonoscopy, laparoscopy or traditional laparotomy from June 2013 to July 2018 in our hospital was performed to analyze CT in the IUD. Observe the position of the contraceptive ectopic position and the accuracy of the positional relationship with the surrounding tissue when ectopic.Results In 28 cases, the accurate CT results and the surgical results were as follows: 14 and 14 cases were located in the bladder,4 or 5 cases of rectal mucosa,Back in blind zone 1, 1 case,5, 5 cases of uterine rectal space,2,2 cases of uterine bladder gap,1, 1 case on the left side of the uterus.Conclusion The multi-row CT and post-processing techniques have a high diagnostic accuracy in the ectopic positioning of the birth control ring, which is helpful for the determination of the preoperative treatment plan.

参考文献/References:

[1]曾琴,李咏梅,李静.36例宫内节育器异位诊治[J].中国生育健康杂志,2014,25(1):71. [2]吴清安,尹晓丹,崔春生,等.宫内节育环异位膀胱2例分析[J].滨州医学院学报,2013,36(4):303. [3]罗敏,高源统,彭文献,等.节育器异位的CT表现[J].放射学实践,2009,24(12):1335. [4]王琨.宫内节育器异位及其诊断[J].国际生殖健康/计划生育杂志,2013,32(1):71-74. [5]马宁.多层螺旋CT三维重建在脊柱急性损伤诊断中的价值[J].实用医技杂志,2016,23(5):492-493.

更新日期/Last Update: 2019-10-01