[1]苏 锋,单国平.2014~2017年浙江省某医院放射工作人员个人剂量监测结果分析[J].医学信息,2019,32(07):140-142.[doi:10.3969/j.issn.1006-1959.2019.07.042]
 SU Feng,SHAN Guo-ping.Analysis of Monitoring Results of Individual Doses To Radiation Workers From 2014 to 2017[J].Journal of Medical Information,2019,32(07):140-142.[doi:10.3969/j.issn.1006-1959.2019.07.042]
点击复制

2014~2017年浙江省某医院放射工作人员个人剂量监测结果分析()
分享到:

医学信息[ISSN:1006-1959/CN:61-1278/R]

卷:
32卷
期数:
2019年07期
页码:
140-142
栏目:
调查分析
出版日期:
2019-04-01

文章信息/Info

Title:
Analysis of Monitoring Results of Individual Doses To Radiation Workers From 2014 to 2017
文章编号:
1006-1959(2019)07-0140-03
作者:
苏 锋单国平
(浙江省肿瘤医院放射物理室,浙江 杭州 310022)
Author(s):
SU FengSHAN Guo-ping
(Department of Radiotherapy Physics,Zhejiang Cancer Hospital,Hangzhou 310022,Zhejiang,China)
关键词:
外照射个人剂量热释光放射防护有效剂量放射工作人员
Keywords:
External exposurePersonal doseThermoluminescenceRadiation protectionEffective doseRadiation workers
分类号:
R144
DOI:
10.3969/j.issn.1006-1959.2019.07.042
文献标志码:
A
摘要:
目的 掌握医院放射工作人员外照射个人剂量水平,为职业辐射防护提供参考依据。方法 以 2014年1月~2017 年12月医院放射工作人员外照射个人剂量值为分析对象,按照《电离辐射防护与辐射源安全基本标准》中的个人剂量限制为标准,依据《职业性外照射个人监测规范》的要求采用热释光方法,在工作时间连续监测全体放射工作人员外照射剂量,对不同工作场所的人员以工作地点为单位进行分组,比较外照射计量水平。结果 放射工作人员4年集体剂量当量为179.12人·mSv,人均年有效剂量为0.44 mSv/年,低于5 mSv/年,其中98.27% 的放射工作人员年有效剂量低于1 mSv/年;18类不同工作场所的放射工作人员中,4年人均年有效剂量最高的是CT室的工作人员,为0.48 mSv/年,其次是1号服务台的工作人员0.36 mSv/年,不同工作场所的工作人员年有效剂量存在较大差异。结论 浙江省某医院医疗放射工作人员的放射防护条件良好,但放射工作人员的防护仍应值得重视,同时应加强放射工作人员的自我保护意识。
Abstract:
Objective To grasp the personal dose level of external radiation of hospital radiation workers, and provide reference for occupational radiation protection.Methods The personal doses of external radiation of hospital radiation workers from January 2014 to December 2017 were analyzed. According to the personal dose limit in "Basic Standards for Protection of Ionizing Radiation and Safety of Radiation Sources", according to "Occupational External Irradiation" The requirements of the Personal Monitoring Regulations adopt the thermoluminescence method to continuously monitor the external exposure dose of all radiation workers during working hours, and group the personnel in different workplaces according to the work place, and compare the external irradiation measurement levels.Results The 4-year collective dose equivalent of radiation workers was 179.12 personomSv, and the annual effective dose per capita was 0.44 mSv/year, which was lower than 5 mSv/year, of which 98.27% of the radiation workers had an annual effective dose of less than 1 mSv/year; Among the radiation workers in 18 different workplaces, the highest annual effective dose per capita for 4 years is the staff of the CT room, which is 0.48 mSv/year, followed by the staff of the No. 1 service desk, 0.36 mSv/year, at different workplaces. There is a large difference in the annual effective dose of the staff.Conclusion The radiation protection conditions of medical radiation workers in a hospital in Zhejiang Province are good, but the protection of radiation workers should still be worthy of attention. At the same time, the awareness of self-protection of radiation workers should be strengthened.

参考文献/References:


[1]中华人民共和国国家质量监督检验检疫总局发布.GB18871电离辐射防护与辐射源安全基本标准:附录B《个人剂量限值》[S].北京:中国标准出版社,2004.
[2]中华人民共和国国家卫生和计划生育委员会发布.GB128职业性外照射个人监测规范[S].北京:中国标准出版社,2016.
[3]中国人民共和国卫生部.GB235放射工作人员职业健康监护技术规范[Z].2011-01-21.
[4]罗强,石圣瑞,李俊娇,等.2008-2015年陕西省部分放射工作人员外照射个人剂量监测结果分析[J].中华放射医学与防护杂志,2017,37(6):466-470.
[5]全国人民代表大会常务委员会发布.中华人民共和国职业病防治法[Z].2017-11-4.
[6]中华人民共和国国家质量监督检验检疫总局.GB18871电离辐射防护与辐射源安全标准[S].北京:中国标准出版社,2003.
[7]中华人民共和国卫生部.GB207外照射个人剂量系统性能检验规范[S].北京:中国标准出版社,2008.
[8]刘慧芳,范东梅.山西省2010-2012年省直管医疗机构放射工作人员外照射个人剂量分析[J].中华放射医学与防护杂志,2013,3(6):655-656.
[9]孙璐,鲍松滨,崔勇,等.2012年辽宁省放射工作人员外照射个人剂量监测结果分析[J].中国辐射卫生,2013,22(6):674-675.
[10]程晓军,田崇彬.河南省2003-2007年放射诊疗工作人员个人剂量水平调查[J].中国辐射卫生,2009,18(3):310-312.
[11]秦永春,杨小勇,陈维,等.江苏省部分放射工作人员外照射个人剂量五年检测结果分析[J].中华放射医学与防护杂志,2015,35(9):702-704.
[12]章雷,王兴功,戚丽华,等.2012-2014年北京部分军队医院放射工作人员异常剂量结果及分析[J].中国辐射卫生,2016,25(3):301-303.

更新日期/Last Update: 2019-04-01