参考文献/References:
[1]Lorenzi-Filho G,Almeida FR,Strollo PJ.Treating OSA:Current and emerging therapies beyond CPAP[J].Respirology,2017,22(8):1500-1507.
[2]Ramar K,Dort LC,Katz SG,et al.Clinical Practice Guideline for the Treatment of Obstructive Sleep Apnea and Snoring with Oral Appliance Therapy:An Update for 2015[J].J Clin Sleep Med,2015,11(7):773-827.
[3]胡碧,王茂筠,王怡唯,等.夜间动态血氧饱和度监测对代谢综合征合并阻塞性睡眠呼吸暂停低通气综合征患者的意义研究[J].中国全科医学,2017,20(11):1287-1293.
[4]Basyuni S,Barabas M,Quinnell T.An update on mandibular advancement devices for the treatment of obstructive sleep apnoea hypopnoea syndrome[J].J Thorac Dis,2018,10(Suppl 1):S48-S56.
[5]Brown EC,Cheng S,McKenzie DK,et al.Respiratory Movement of Upper Airway Tissue in Obstructive Sleep Apnea[J].Sleep,2013,36(7):1069-1076.
[6]Edwards BA,Andara C,Landry S,et al.Upper-airway collapsibility and loop gain predict the response to oral appliance therapy in obstructive sleep apnea patients[J].Am J Respir Crit CareMed,2016,194(11):1413-1422.
[7]Anandam A,Patil M,Akinnusi M,et al.Cardiovascular mortality in obstructive sleep apnoea treated with continuous positive airway pressure or oral appliance:an observational study[J].Respirology,2013,18(8):1184-1190.
[8]赵健,张宗德.口腔矫治器治疗OSAHS的适应证和疗效评价临床研究[J].医学论坛杂志,2016,37(6):55-58.
[9]Martins OFM,Chaves Junior CM,Rossi RRP,et al.Side effects of mandibular advancement splints for the treatment of snoring and obstructive sleep apnea:a systematic review[J].Dental Press J Orthod,2018,23(4):45-54.
[10]Bratton DJ,Gaisl T,Wons AM,et al.CPAP vs mandibular advancement devices and blood pressure in patients with obstructive sleep apnea:a systematic review and meta-analysis[J].JAMA,2015,314(21):2280-2293.
[11]Dal-Fabbro C,Garbuio S,D'Almeida V,et al.Mandibular advancement device and CPAP upon cardiovascular parameters in OSA[J].Sleep Breath,2014,18(4):749-759.
[12]Phillips CL,Grunstein RR,Darendeliler MA,et al.Health outcomes of continuous positive airway pressure versus oral appliance treatment for obstructive sleep apnea:a randomized controlled trial[J].Am J Respir Crit Care Med,2013,187(5):879-887.
[13]管增娥,姜稳妮,杨永国,等.口腔矫治器治疗OSAHS合并高血压的临床疗效[J].实用口腔医学杂志,2014,30(4):568-569.
[14]Lin CC,Wang HY,Chiu CH,et al.Effect of oral appliance on endothelial function in sleep apnea[J].Clin Oral Investig,2015,19(2):437-444.
[15]de Vries GE,Wijkstra PJ,Houwerzijl EJ,et al.Cardiovascular effects of oral appliance therapy in obstructive sleep apnea:A systematic review and meta-analysis[J].Sleep Med Rev,2018,40(10):55-68.
[16]夏春鹏,林燕辉,李岩,等.口腔矫治器治疗OSAHS患者焦虑抑郁及心理状态影响的研究[J].山东大学耳鼻喉学报,2014,28(2):29-32.
[17]腾雍辉,张沙沙,张佐,等.OSAHS患者经口腔矫治器治疗前后心理状况改变的临床研究[J].宁夏医学杂志,2014,36(6):505-507.
[18]Sarkhosh K,Switzer NJ,El-Hadi M,et al.The impact of bariatric surgery on obstructive sleep apnea:a systematic review[J].Obes Surg,2013,23(3):414-423.
[19]Schell TG.Avoiding and Managing Oral Appliance Therapy Side Effects[J].Sleep Med Clin,2018,13(4):503-512.
[20]Aarab G,Lobbezoo F,Hamburger HL,et al.Effects of an oral appliance with different mandibular protrusion positions at a constant vertical dimension on obstructive sleep apnea[J].Clin Oral Investig,2010,14(3):339-345.
[21]Hamoda MM,Almeida FR,Pliska BT.Long-term side effects of sleep apnea treatment with oral appliances:nature,magnitude and predictors of long-term changes[J].Sleep Med,2019(56):184-191.
[22]Doff MH,Finnema KJ,Hoekema A,et al.Long-term oral appliance therapy in obstructive sleep apnea syndrome:a controlled study on dental side effects[J].Clin Oral Investig,2013,17(2):475-482.
[23]Pliska BT,Nam H,Chen H,et al.Obstructive sleep apnea and mandibular advancement splints: occlusal effects and progression of changes associated with a decade of treatment[J].J Clin Sleep Med,2014,10(12):1285-1291.
[24]Marklund M.Update on Oral Appliance Therapy for OSA[J].Curr Sleep Med Rep,2017,3(3):143-151.
[25]Perez CV,de Leeuw R,Okeson JP,et al.The incidence and prevalence of temporomandibular disorders and posterior open bite in patients receiving mandibular advancement device therapy for obstructive sleep apnea[J].Sleep Breath,2013,17(1):323-332.
[26]Suzuki K,Nakata S,Tagaya M,et al.Prediction of oral appliance treatment outcome in obstructive sleep apnoea syndrome:a preliminary study[J].B-ENT,2014,10(3):185-191.
[27]Ng AT,Qian J,Cistulli PA.Oropharyngeal collapse predicts treatment response with oral appliance therapy in obstructive sleep apnea[J].Sleep,2006,29(5):666-671.
[28]Lee CH,Jung HJ,Lee WH,et al.The effect of positional dependency on outcomes of treatment with a mandibular advancement device[J].Arch Otolaryngol Head Neck Surg,2012,138(5):479-483.
[29]Ng AT,Darendeliler MA,Petocz P,et al.Cephalometry and prediction of oral appliance treatment outcome[J].Sleep Breath,2012,16(1):47-58.
[30]Ringqvist M,Walker-Engstrom ML,Tegelberg A,et al.Dental and skeletal changes after 4 years of obstructive sleep apnea treatment with a mandibular advancement device:a prospective, randomized study[J].Am J Orthod Dentofac Orthop,2003,124(1):53-60.
[31]Sharples LD,Clutterbuck-James AL,Glover MJ,et al.Meta-analysis of randomised controlled trials of oral mandibular advancement devices and continuous positive airway pressure for obstructive sleep apnoea-hypopnoea[J].Sleep Med Rev,2016,27(5):108-124.
[32]Galic T,Bozic J,Pecotic R,et al.Improvement of Cognitive and Psychomotor Performance in Patients with Mild to Moderate Obstructive Sleep Apnea Treated with Mandibular Advancement Device: A Prospective 1-Year Study[J].J Clin Sleep Med,2016,12(2):177-186.
[33]Saglam-Aydinatay B,Taner T.Oral appliance therapy in obstructive sleep apnea:Long-term adherence and patients'experiences[J].Med Oral Patol Oral Cir Bucal,2018,23(1):e72-e77.
相似文献/References:
[1]邹海涛,李永霞.普通人群及医务人员OSAHS认知现状及
相关因素的研究进展[J].医学信息,2018,31(14):24.[doi:10.3969/j.issn.1006-1959.2018.14.009]
ZOU Hai-tao,LI Yong-xia.Research Progress of OSAHS Cognition Status and Related Factors among General Population and Medical Staff[J].Journal of Medical Information,2018,31(11):24.[doi:10.3969/j.issn.1006-1959.2018.14.009]
[2]李露娜,周青松.不同性别OSAHS患者的睡眠质量对血压的影响[J].医学信息,2018,31(20):69.[doi:10.3969/j.issn.1006-1959.2018.20.020]
LI Lu-na,ZHOU Qing-song.Effect of Sleep Quality on Blood Pressure in OSAHS Patients with Different Genders[J].Journal of Medical Information,2018,31(11):69.[doi:10.3969/j.issn.1006-1959.2018.20.020]
[3]潘悦达,王东博,韩德民.我国成人阻塞性睡眠呼吸暂停低通气综合征患病率的Meta分析[J].医学信息,2019,32(07):73.[doi:10.3969/j.issn.1006-1959.2019.07.022]
PAN Yue-da,WANG Dong-bo,HAN De-min.Meta-analysis of the Prevalence of Adult Obstructive Sleep Apnea Hypopnea Syndrome in China[J].Journal of Medical Information,2019,32(11):73.[doi:10.3969/j.issn.1006-1959.2019.07.022]
[4]刘 爽.鼻腔扩容术对OSAHS的疗效及对咽部软腭长度的影响[J].医学信息,2019,32(15):104.[doi:10.3969/j.issn.1006-1959.2019.15.033]
LIU Shuang.Effect of Nasal Cavity Expansion on the Treatment of Patients with OSAHS and the Effect on
the Length of Pharyngeal Soft Palate[J].Journal of Medical Information,2019,32(11):104.[doi:10.3969/j.issn.1006-1959.2019.15.033]
[5]李相德.悬雍垂腭咽成形术联合持续正压通气治疗阻塞性睡眠呼吸暂停低通气综合征患者的效果[J].医学信息,2020,33(20):107.[doi:10.3969/j.issn.1006-1959.2020.20.032]
LI Xiang-de.Uvulopalatopharyngoplasty Combined with Continuous Positive Pressure Ventilation in the Treatment of Patients with Obstructive Sleep Apnea Hypopnea Syndrome[J].Journal of Medical Information,2020,33(11):107.[doi:10.3969/j.issn.1006-1959.2020.20.032]
[6]高俊康,万玉峰.阻塞性睡眠呼吸暂停低通气综合征患者病情严重程度与血液学指标的相关性分析[J].医学信息,2021,34(04):84.[doi:10.3969/j.issn.1006-1959.2021.04.022]
GAO Jun-kang,WAN Yu-feng.Correlation Analysis Between the Severity of Illness and Hematological Indexes in Patients with Obstructive Sleep Apnea Hypopnea Syndrome[J].Journal of Medical Information,2021,34(11):84.[doi:10.3969/j.issn.1006-1959.2021.04.022]
[7]刘腾雁,戴丽芬,彭娅萍,等.缺氧诱导因子-1α对OSAHS患者糖代谢的影响研究[J].医学信息,2023,36(01):189.[doi:10.3969/j.issn.1006-1959.2023.01.042]
LIU Teng-yan,DAI Li-fen,PENG Ya-ping,et al.Effect of Hypoxia-inducible Factor-1α on Glucose Metabolism in Patients with OSAHS[J].Journal of Medical Information,2023,36(11):189.[doi:10.3969/j.issn.1006-1959.2023.01.042]